Bus system SAE J1939 license
21052
Regular price £627.00 Save Liquid error (product-template line 131): Computation results in '-Infinity'%CAN-Bus Tester 2
21012
Regular price £3,972.90 Save Liquid error (product-template line 131): Computation results in '-Infinity'%The CAN-Bus Tester 2 is a widely used measuring device for control of bus parameters. The success story starts already in the year 2002 with the first model. The hardware was completely redesigned in version 2. The corresponding software is still developed and has been enhanced with extensive updates.
Check the setup of the bus before you switch on with the bus wiring test, measure under running conditions down on the physical layer and analyses data of the nodes with the protocol monitor. The longtime monitor shows scattered errors and creeping signal loss.
The trigger output makes it possible to show data from only one node of the bus.
The great box contents within the service case with big adapter set make it possible to use the device out of the box in many environments. You can save your measurements and print a status protocol directly from the software.
Bus systems | CAN (ISO11898‑2), CANopen (CiA301), DeviceNet (EN 50325 – 2), SAE J1939 |
Bit sampling | 64-fold, 10,240 sampling points |
Bit timing | Adjustable BTL cycles (tq), sample point and resynchronization jump width (SJW) |
Supported baud rates |
Depending on bus system: 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s Additionally user-defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s Automatic detection via baud rate scan |
List of stations |
Automatic detection via Station scan Designation, CAN ID, ID type, Node ID, MAC ID, Source address, can also be entered manually |
List of Measurements |
Possibility to measure at different measuring points and at different times Sorting by measurement type, measuring point and measurement time |
Quality level |
Value representing the signal quality (0 …100%) The minimum value and maximum values saved timestamp |
Disturbance-free voltage range and edges |
Disturbance-free voltage range (typ. ‑0.75 … 3 V, resolution 50 mV) Edge steepness (falling and rising, specified in 1/64th of the bit width) The minimum value and maximum values saved |
Oscilloscope display |
Trigger on message frames with the specified ID, trigger position can be set Frame analysis and full frame recording Decoding according to the protocol (CAN, CANopen, DeviceNet, SAE J1939) Zoom (six stages) |
Online Trigger |
Real-time monitoring of the bus for logical and physical errors Resolution can be set (10 ms … 1 min) Oscilloscope display and e‑mail notification on triggers |
Automatic evaluation |
Limit value settings and measured-value evaluation according to:
• critical quality level |
Bus status | Bus traffic detection (display: dominant, recessive, not defined, bus traffic) |
Bus traffic load |
Permanent display of the bus traffic load (0 … 100%), Minimum and maximum values saved |
Error frames |
Constant display of detected frame errors Distinction between active and passive error frames (0 … >50,000) |
Protocol monitor |
CAN: Reception of CAN message frames incl. filtering, Transmission of CAN message frames and sequences (message lists) CANopen: Interpretation of all CAN messages according to the CANopen spec as SDOs, PDOs, NMT‑, Heartbeat‑, Emergency‑, Sync- and Timestamp (CiA301, CiA302, CiA305, CiA401, CiA402, CiA404, CiA406, CiA408, CiA410, upgradeable) |
Test record |
Comprehensive, configurable measuring and test record on DIN A4:
• Letterhead with tester and customer contact data |
Export function |
Measuring data as a configurable CSV file Graphical measured-data representation as a configurable bitmap (.bmp,.jpg,.png) |
Firmware and FPGA configuration | can be updated via USB |
Electrical parameters | |
Power supply | Via the supplied wide-range power supply (9 … 36 V DC) |
Current consumption | 0.55 … 0.15 A |
Measuring of the differential voltage | typ. ‑0.75 V … 3.00 V |
Measuring of the loop resistances | typ. 0 Ω … 800 Ω |
Measuring of the cable length |
typ. 0 m … 500 m
• 0…100 m: Resolution: 0.5 m, Accuracy: 3 % ± 1.5 m • 100…500 m: Resolution: 1.0 m, Accuracy: 10 % ± 10 m for a signal runtime of: 4.5 ns/m for CAN/CANopen/SAE J1939, 4.3 ns/m for DeviceNet |
Measuring of the CAN supply voltage | 0 … 36 V |
Potential difference between the connections CAN bus, USB and oscilloscope | < 50 V DC (or < 71 V AC) |
Trigger output for the oscilloscope | BNC socket, electrically isolated, H pulse, approx. 2 bits wide, level approx. 5 V |
Mechanical parameters | |
Supply voltage connection | Extra-low voltage socket |
CAN connection | 2 x 9‑pin D‑Sub connector |
PC connection | Self-powered device to USB Specification 1.1, electrically isolated |
Trigger output for oscilloscope |
BNC socket, electrically isolated |
Housing | Aluminum sheet housing |
Temperature range | Operation: 5 °C … 40 °C Storage: ‑20 °C … 60 °C |
Humidity | Operation: 20 % … 80 % (non-condensing) Storage: 20 % … 80 % (non-condensing) |
Degree of protection of the housing | IP20 to EN 60529 |
Dimensions (Device /Case) | 170 mm x 134 mm x 40 mm /504 mm x 354 mm x 119 mm |
Weight (Device /Case) | Approx. 600 g /Approx. 5000 g |
Warning:The CBT2 is a Class A device. Such devices can cause interference in residential areas. In this case, the plant operator can be required to take appropriate measures and to bear the costs of such measures. |
CAN-bus Tester 2 - Complete Set
15004
Regular price £8,240.10 Save Liquid error (product-template line 131): Computation results in '-Infinity'%The CAN-Bus Tester 2 is a widely used measuring device for control of bus parameters. The success story starts already in the year 2002 with the first model. The hardware was completely redesigned in version 2. The corresponding software is still developed and has been enhanced with extensive updates.
Check the setup of the bus before you switch on with the bus wiring test, measure under running conditions down on the physical layer and analyses data of the nodes with the protocol monitor. The longtime monitor shows scattered errors and creeping signal loss.
The trigger output makes it possible to show data from only one node of the bus.
The great box contents within the service case with big adapter set make it possible to use the device out of the box in many environments. You can save your measurements and print a status protocol directly from the software.
This set contains all bus systems and protocol monitor licences (CANopen, CAN, DeviceNet and SAE J1939).
CANalarm basic set
21062
Regular price £322.05 Save Liquid error (product-template line 131): Computation results in '-Infinity'%The CANalarm is an inexpensive analysis tool that can be permanently installed in the bus.
It allows the establishment of independent redundant monitoring without interfering with the configuration and programming of the controller. It works passively on the bus and is therefore non-reactive.
The complete device is housed in a CAN-D-Sub 9 connector. The Autobaud function makes it easy to use.
The application possibilities of the CANalarm are manifold. In the following, we will go into it further.
CANobserver
21054
Regular price £1,315.75 Save Liquid error (product-template line 131): Computation results in '-Infinity'%The CANobserver is a diagnosis tool for the physical and logical long-term monitoring of CAN bus systems and is designed as a stationary supplement to the CAN bus tester 2.
Once the system is at a standstill, the damage is usually great.
In order to be able to initiate countermeasures in good time, both the plant components and the pipeline system as a whole should be continuously maintained. Due to wear, the operating parameters of the bus system deteriorate. Our CANobserver diagnoses such changes during operation and reports them to the plant operator.
24V SELV
Languages: | German, English |
Bus: | CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325 – 2), SAE J1939 |
Bit sampling: | 64x, 10240 sampling points |
Bittiming: | BTL cycles (tq), sampling time and synchronization jump distance (SJW) adjustable |
Supported baud rates according to bus system: | 10; 20; 50; 100; 125; 250; 500; 800; 1000 kBit/s |
additionally user-defined: 5; 33,3; 62,5; 75; 83,3; 200 kBit/s | |
automatic detection by baud rate scan, bit timing adjustable | |
Bus status | Bus traffic detection (display: dominant, recessive, undefined, level change, valid bus traffic) |
Display of bus utilization (0 ... 100 %) | |
History, minimum and maximum value storage | |
Bus Error | Display of detected telegram errors |
Differentiation between active and passive error frames (0 ... >50,000), history display | |
Bus voltages | Display of the optional CAN supply voltage and the shielding voltage |
History, minimum and maximum value storage | |
Common-mode voltage | Detection of the maximum voltage offset between the individual bus participants |
CAN level (Absolute /Differential) | Recording and evaluation of the differential and absolute CAN levels of all bus devices |
Measurement of participants | Participant-specific measurements |
Quality value (value of signal quality), interference voltage distance, slope (falling and rising) as well as oscilloscope display with telegram analysis | |
Measurement Online Trigger | Error analysis with adjustable evaluation limits, variable time slices and trigger function |
Log Monitor | Sending and receiving CAN telegrams |
Electrical parameters |
|
Power and battery* | Integrated rechargeable lithium-ion battery Ext. Supply input: SELV DC voltage 14 V, internally fused with 2.5 A Operation only via supplied 35 W wide-range power supply Type: SAW-14.0 – 2500 Runtimes: Standby: up to 500 hours Use: up to 36 hours Measuring: up to 6 hours Charging times: fast charging to 80 % in about 1 hour complete charging in about 2 hours. |
Potential difference between the CAN bus and USB connections | 500 V AC |
Voltage between any two connections on the CAN or external ground connection | ±30 V DC |
Measurements |
Range | Resolution | Accuracy (typ.) |
Quality value | 0,0 % ... 100,0 % | 0.3 g | - |
Flank steepness | 0/64 ... 64/64 | 1/64 | - |
Measurement of the interference voltage distance | -0.75 V ... +3.25 V | 0.05 V | 1.90 % ±100 mV |
Measurement of differential voltage | -0.75 V ... +3.25 V | 0.01 V | 0.50% ±10 mV (calibrated) |
Measurement of absolute voltage | -5.00 V ... +10.00 V | 0.05 V | 0.50% ±50 mV (calibrated) |
Measurement of shielding voltage | -10.0 V ... +1.0 V | 0.1 V | 0.25% ±100 mV (calibrated) |
Measurement of the CAN supply voltage | 0.0 V ... 32.0 V | 0.1 V | 0.25% ±100 mV (calibrated) |
Measurement of loop resistances | 0 Ω ... 100 Ω 100 Ω ... 1000 Ω |
0.1 Ω 1.0 Ω |
0.85% ±0.2% Ω 0.85% ±2.0 Ω |
Measurement of cable length | 2 m ... 1000 m | 1 m | 5 % ±2 m (runtime: 4.5 ns/m) |
Mechanical parameters |
|
Connection power supply | Low voltage socket |
Connection CAN | 9-pin. D-Sub Connector |
USB connection | Self-Powered Device according to USB 2.0 specification, Full Speed, galvanically isolated Registration of a drive for measurement data exchange (USB Mass Storage Device) |
Case | Aluminium housing, cover glass |
Ambient conditions | Operating temperature : 5 °C ... 40 °C storage temperature : -20 °C ... 60 °C humidity: 5 % ... 95%, non-condensing |
Enclosure protection class | IP20 according to EN 60529 |
Dimensions | 186 mm x 102 mm x 37 mm |
Mass | approx. 860 g |
CANtouch Adapter Set
21056
Regular price £517.75 Save Liquid error (product-template line 131): Computation results in '-Infinity'%Robust CAN cables with high-quality, fully shielded crimp connectors.
Cable D-Sub9 to M12, 30cm
Cable D-Sub9 to M12, 150cm
T-Adapter M12 to D-Sub9, Full Metal
T-Adapter M12, Full Metal
Short Circuit Plug M12 (for Wiring Test)
Short Circuit Plug D-Sub9 (for Wiring Test)
Termination Resistor M12
Terminating Resistor D-Sub9
Ground Connection Cable with Probe and Clamp
CANtouch basic set
21055
Regular price £2,544.10 Save Liquid error (product-template line 131): Computation results in '-Infinity'%CANtouch incl. power supply (type: SAW-14.0 – 2500), power connection cable Euro,
USB cable, 2 manuals (German, English)
The further development of the CAN-Bus Tester 2 is battery-powered and equipped with a touch display. Its intuitive user interface allows extensive measurements to be taken in the shortest possible time. The results can be archived for documentation or later analysis and further processed on the PC.
The physical layer measurements have been extended to include the direct determination of potential differences between the participants (common mode/ground shift).
With the online trigger, you can monitor the bus for individual physical limits, determine problems over time and make errors visible in the oscillogram.
The protocol monitor is used for sending, receiving, decoding, and recording messages.
Languages: | German, Englisch |
Bus systems: | CAN (ISO11898‑2), CANopen (CiA301), DeviceNet (EN 50325 – 2), SAE J1939 |
Bit sampling : | 64-fold, 10240 sampling points |
Bit timing: | Adjustable BTL cycles (tq), sample point and resynchronization jump width (SJW) |
Supported baud rates | Depending on bus system: 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s |
Additionally user-defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s | |
Automatic detection via baud rate scan, bit timing adjustable | |
Bus status | Bus traffic detection (display: dominant, recessive, not defined, bus traffic) |
Display of the Bus traffic load (0 … 100 %) | |
characteristic, minimum and maximum value saving | |
Bus errors | Display of detected frame errors |
Distinction between active and passive error frames (0 … >50,000), trend chart | |
Bus voltages | Display of the optional CAN supply voltage and shield voltage |
Characteristic, minimum and maximum value saving | |
Common mode voltage | Acquisition of the maximum voltage offset between the individual bus nodes |
CAN level (absolute /differential) | Acquisition and evaluation of the differential and absolute CAN levels of all bus nodes during operation |
Node measurement | Node related measurements |
Quality value (signal quality), Disturbance-free voltage range, Edge steepness (falling and rising) and Oscilloscope display with message frame analysis |
|
Online Trigger | Error analysis with adjustable values, variable time slices and trigger function |
Protocol monitor | Send and receive of CAN messages |
Electrical parameters |
|
Power supply and battery* | Integrated, rechargeable lithium-ion battery External power input: SELV d.c. voltage 14 V, internal fused with 2.5 A Operating with the supplied 35 W wide-range power supply unit only (SAW-14.0 – 2500) Times-to-empty: Standby: up to 500 hours Use: up to 36 hours Measuring: up to 6 hours Charge times: Quick charge to 80% in approx. 1 h Full charge in approx. 2 h |
Potential difference between the CAN bus and USB connections | < 500 V AC |
Voltage between any two terminals of the CAN connection or external ground, resp. | < ±30 V DC |
Measurements |
Range | Resolution | Accuracy (typ.) |
Quality value | 0,0 % … 100,0 % | 0,1 % | - |
Edge steepness | 0/64 … 64/64 | 1/64 | - |
Disturbance-free voltage range | -0,75 V … +3,25 V | 0,05 V | 1,90 % ±100 mV |
Measuring of the differential voltage | -0,75 V … +3,25 V | 0,01 V | 0,50 % ±10 mV (calibrated) |
Measuring of the absolute voltage | -5,00 V … +10,00 V | 0,05 V | 0,50 % ±50 mV (calibrated) |
Measuring of the shield voltage | -10,0 V … +1,0 V | 0,1 V | 0,25 % ±100 mV (calibrated) |
Measuring of the CAN supply voltage | 0.0 V … 32,0 V | 0,1 V | 0,25 % ±100 mV (calibrated) |
Measuring of the loop resistances | 0 Ω … 100 Ω 100 Ω … 1000 Ω |
0,1 Ω 1,0 Ω |
0,85 % ±0,2 Ω 0,85 % ±2,0 Ω |
Measuring of the cable length | 2 m … 1000 m | 1 m | 5 % ±2 m (signal propagation delay: 4.5 ns/m) |
Mechanical parameters |
|
Power supply unit connection | Extra-low voltage socket |
CAN connection | 9‑pin D‑Sub connector |
PC connection | Self-powered device to USB Specification 2.0, full speed, in addition, electrically isolated Connection of a drive for exchange of measuring data (USB mass storage device) |
Housing | Aluminum housing, cover glass |
Ambient conditions | Operation temperature: 5 °C … 40 °C Storage temperature: ‑20 °C … 60 °C Atmospheric humidity: 20 % … 80 %, non-condensing |
Degree of protection of the housing | IP20 to EN 60529 |
Dimensions | 186 mm x 102 mm x 37 mm |
Weight | Approx. 860 g |
CANtouch Complete Set
21001
Regular price £3,372.74 Save Liquid error (product-template line 131): Computation results in '-Infinity'%The CANtouch is a mobile measuring device for CAN-based bus systems.
The further development of the CAN-Bus Tester 2 is battery-operated and equipped with a touch display. Its intuitive program interface enables extensive measurements in the shortest possible time. The results can be archived for documentation or later analysis and further processed on the PC.
The measurements of the bus physics were extended by the direct determination of the potential differences between the participants (common mode / mass offset).
With the Online Trigger you can monitor your bus for individual physical limits, limit problems in time and make errors visible in the oscillogram.
The Log Monitor is used to send, receive, decode, and record messages.
Complete set consisting of:
• CANtouch – basic set (PR-22580 – 00)
• adapter set (PR-22580 – 10)
• service case (PR-22580 – 50)
CANvision
21069
Regular price £503.50 Save Liquid error (product-template line 131): Computation results in '-Infinity'%is the most widely used CAN software tool in our company. It is used in the development, commissioning and monitoring of CAN networks. Due to the network capability, not even the presence at the measuring site is necessary for use.
See and analyze the traffic, filter, send your own telegrams.
Visit our store page to see the full range of collections we offer. Some of our best sellers include:
- PEAK System Technik GmbH
- Kunbus
- CSS Electronics
- Deep Sea Electronics