PCAN-LIN Specifications

Download User Manual

Specifications

  • General-purpose gateway (or router when using Acceptance Code / Acceptance Mask feature) from:
    • RS-232 to LIN (and back)
    • CAN to LIN (and back)
    • RS-232 to CAN (limited bandwidth)
  • CAN bit rates up to 1 Mbit/s
  • Complies with CAN specifications 2.0 A/B
  • LIN bit rates of 1 – 20 kbit/s
  • Transmitting/receiving LIN 1.x and 2.x frames
  • Available for use as LIN master or slave
  • Simulation of LIN slaves. Data can be changed via CAN frames
  • Processing a user-definable LIN ID list (scheduler with limited number of entries)
  • Individual LIN frames can be initiated via CAN or RS-232
  • Voltage supply from 9 to 30 V
  • Extended operating temperature range
    from -40 to 85 °C (-40 to 185 °F)

Optionally available:

  • High-speed (ISO 11898-2) or Low-speed (ISO 11898-3) CAN transceiver module
  • Galvanic isolation between RS-232 and CAN/LIN up to 1 kV (only for High-speed CAN)

Pin assignment Female D-Sub Connector

Pin Pin assignment RS-232
1 Not connected
2 TxD (RS-232-level)
3 RxD (RS-232-level)
4 Not connected
5 GND
6 Not connected
7 Not connected
8 Not connected
9 Not connected

Pin assignment Male D-Sub Connector

Pin Pin assignment CAN/LIN
1 VBat 9 - 30V (Imax ~ 130mA)
2 CAN-L
3 GND
4 LIN data
5 Not connected
6 GND
7 CAN-H
8 Not connected
9 Not connected