PCAN-LIN Specifications
Specifications
- General-purpose gateway (or router when using Acceptance Code / Acceptance Mask feature) from:
- RS-232 to LIN (and back)
- CAN to LIN (and back)
- RS-232 to CAN (limited bandwidth)
- CAN bit rates up to 1 Mbit/s
- Complies with CAN specifications 2.0 A/B
- LIN bit rates of 1 – 20 kbit/s
- Transmitting/receiving LIN 1.x and 2.x frames
- Available for use as LIN master or slave
- Simulation of LIN slaves. Data can be changed via CAN frames
- Processing a user-definable LIN ID list (scheduler with limited number of entries)
- Individual LIN frames can be initiated via CAN or RS-232
- Voltage supply from 9 to 30 V
- Extended operating temperature range
from -40 to 85 °C (-40 to 185 °F)
Optionally available:
- High-speed (ISO 11898-2) or Low-speed (ISO 11898-3) CAN transceiver module
- Galvanic isolation between RS-232 and CAN/LIN up to 1 kV (only for High-speed CAN)
Pin assignment Female D-Sub Connector
Pin | Pin assignment RS-232 |
---|---|
1 | Not connected |
2 | TxD (RS-232-level) |
3 | RxD (RS-232-level) |
4 | Not connected |
5 | GND |
6 | Not connected |
7 | Not connected |
8 | Not connected |
9 | Not connected |
Pin assignment Male D-Sub Connector
Pin | Pin assignment CAN/LIN |
---|---|
1 | VBat 9 - 30V (Imax ~ 130mA) |
2 | CAN-L |
3 | GND |
4 | LIN data |
5 | Not connected |
6 | GND |
7 | CAN-H |
8 | Not connected |
9 | Not connected |